Description
6kVA/5.4kW/208V Battery Backup for IT Installations and Edge Networks
This SmartOnline® rack-mount online double-conversion UPS system provides uninterrupted battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage valuable IT equipment or destroy data. The SU6000RTMB provides reliable power management for education, commercial, financial or healthcare networking components, including Cisco switches and servers.
Expandable Internal Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable valve regulated lead acid (VRLA) battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Automatic restart after power outages reduces costly on-site visits. You can also connect up to four extended battery modules (BP180RT, sold separately) for hours of extended runtime.
Included Bypass Switch Isolates UPS from Connected Loads for Maintenance
The manual bypass lets you remove the UPS for maintenance without disrupting power to the connected load. The bypass reroutes utility power to keep essential equipment operational while you're servicing or replacing the UPS system.
Pre-Installed Network Interface Offers 24/7 Remote Access
The WEBCARDLXE network interface turns the SU6000RTMB into a managed device on your network. It enables full remote configuration and SNMP-based UPS management, including load shedding, safe shutdowns and automated alerts. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment without an on-site visit. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
NEMA Outlets Protect Your Connected Components
Two L6-20R and two L6-30R managed outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The SU6000RTMB also supports hardwired output.
Intuitive LCD Interface Keeps You Informed at a Glance
The menu-driven LCD provides control settings and critical information to help diagnose any issues, including alarm and fault notifications. The interface rotates to accommodate both rack-mount and tower configurations, and it tilts up to 45 degrees for more comfortable viewing.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a serial-enabled device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO connectors permit emergency shutdown or remote restart of all connected equipment.
Versatile Installation Options
You can mount the SU6000RTMB in 3U of space in an EIA-standard 19-inch rack using the included 4-post rail kit or an optional 2-post rail kit (RK2PC, sold separately, one required for each UPS or EBM). You can also adapt it for tower installation using the included support stands. The 10-foot power cord with NEMA L6-30P plug connects to a compatible AC outlet. A cable gland is included for alternate hardwire input.
- Protects equipment against blackouts, brownouts, transient surges and line noise
- Keeps equipment running during outages to allow time for file saves and safe shutdown
- Pre-installed WEBCARDLXE network card enables full remote access and control
- Included bypass switch allows uninterrupted operation during UPS maintenance
- Optional extended battery modules allow extended runtime to keep equipment powered
- 2-year limited warranty
- $250,000 Ultimate Lifetime Insurance
Specifications
Specifications
-
Environmental CertificationRoHS
-
Environmentally FriendlyYes
-
Limited Warranty2 Year
-
Form FactorRack/Tower
-
Energy StarYes
-
Product LineSmartOnline
-
Cord Length10 ft
-
Hot SwappableYes
-
Rack Height3U
-
Input Voltage230 V AC
-
USBYes
-
Serial PortYes
-
Battery ChemistryLead Acid
-
Backup/Run Time (Full Load)3 Minute
-
Transfer Time0 ns
-
AVRYes
-
PhaseSingle Phase
-
Waveform TypePure Sine Wave
-
Replaceable BatteryYes
-
Backup/Run Time (Half Load)8 Minute
-
DisplayLCD
-
Battery CharacteristicsValve-regulated
-
Minimum Operating Temperature32°F (0°C)
-
Maximum Operating Temperature104°F (40°C)
-
Receptacle Detail2 x NEMA L6-20R,2 x NEMA L6-30R
-
Plug/Connector TypeNEMA L6-30P,Hardwired
-
Receptacle TypeNEMA L6-20R,NEMA L6-30R,Hardwired
-
ManufacturerTripp Lite by Eaton
-
Circuit BreakerYes
-
Product TypeDouble Conversion Online UPS
-
EMI/RFI Noise FilterYes
-
DC System Voltage180 V DC
-
Output Power Factor0.9
-
Manufacturer Website Addresshttps://tripplite.eaton.com/
-
Output Frequency50 Hz,60 Hz
-
Additional Warranty Information$250,000 Ultimate Lifetime Insurance
-
Surge SuppressionYes
-
Output Voltage230 V AC,240 V AC,220 V AC,208 V AC,200 V AC,100 V AC,110 V AC,120 V AC
-
Input Current24.80 A
-
Network ManagementNetwork Card,DB-9 RS-232,Dry Contact,USB,SNMP
-
Package ContentsSmartOnline SU6000RTMB 6000VA Rack/tower UPS SUPDMBP6K Maintenance Bypass WEBCARDLXE Network Card USB Cable RS-232 Cable Tower Support Stands Cable Gland for Hardwire Connection Rack-mounting Hardware Maintenance Bypass Mounting Hardware DB9 Serial Cables Quick Start Guide
-
Thermal Dissipation555.37 W
-
Product ModelSU6000RTMB
-
FeaturesAudible Alarm,Cold Start Function,Green Energy Saving,Built-in Bypass Switch
-
Efficiency Detail98% (ECO Mode)
-
AlarmUtility Power Failure,Low Battery,Overload,Battery Fault,Remote Shutdown
-
Application/UsageMission Critical Equipment,IT Equipment,Network Device,Education,Commercial,Financial,Healthcare
-
Status IndicatorsLED Indicators: 4 status-indicating LEDs
-
Load Capacity (VA)6000 VA
-
Load Capacity (Watt)5400 W